778035-2026 · Contract Notice
Integrated systemic perfusion system designed for an extracorporeal circulation machine.
Integrated systemic perfusion system designed for an extracorporeal circulation machine.
PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES
- Location
- Skopje, North Macedonia
- Service Period
1 year
- Contract value
- MKD 10,996,480
- Publication
- Today
- Deadline
Only 18 days remaining until submission deadline!
Sterile extracorporeal perfusion system and oxygenator
Supply sterile adult perfusion systems for extracorporeal circulation, including specified venous, arterial, suction and monitoring lines, accessories, blood transfer bag, reservoir level sensor, oxygenator and blood cardioplegia set. Components must comply with the detailed material, dimensions, capacities, connectors and tolerance requirements.
✨ AI Insights
💰 Realistic Cost Estimate
MKD 9,347,010
⏱️ Time to Completion
XXXXXXXX XXXXXXXXX XXXXXXX XXXXXXXXXX XXXXX
⚠️ Risk Factors
XXXXXXXX XXXXXXXXX XXXXXXX XXXXXXXXXX XXXXX
Full AI insights available with PLUS
Sterile Perfusion System
Oxygenator
Blood Cardioplegia Set
Lots1
Lot: LOT-0001
- Title
- Integrated systemic perfusion system designed for an extracorporeal circulation machine.
- Description
- Sterile Perfusion System Venous Line For the drainage of blood from the patient, through the venous cannula, to the cardiotomy reservoir, a venous line made of PVC tubing with an internal diameter of 1/2 inch shall be provided. Measured from the oxygenator, the initial segment shall be 45 cm long (±5%). It shall be followed by a connector with a shunt to the arterial line, and then by tubing 240 cm long (±5%), which connects to the terminal end of the arterial line. The venous line shall not be equipped with a saturation sensor. Arterial Line The return of oxygenated blood from the oxygenator to the patient, through the arterial cannula, shall be performed via an arterial line made of PVC tubing with an internal diameter of 3/8 inch. Starting from the oxygenator, the first segment shall be 55 cm long (±5%), followed by a connector with a shunt to the venous line. After the connector, the tubing shall continue for 200 cm (±5%) and shall be connected to the terminal end of the venous line via a 3/8 × 1/2 inch connector. Arteriovenous Shunt The shunt between the arterial and venous lines shall have an internal diameter of 1/4 inch and shall be equipped with a Robertson clamp. Line Holder An independent line holder, not attached to the tubing, shall be included, with a capacity for at least five lines. The holder shall allow positioning of the arterial and venous lines, suction line, vent line and external suction line within the surgical field. Suction Line The suction line shall be colour-coded and shall have the following configuration: Initial segment made of PVC tubing with an internal diameter of 1/4 inch and a length of 100 cm. 1/4 × 3/8 inch connector for connection to silicone tubing with an internal diameter of 3/8 inch and a length of 60 cm. 3/8 × 1/4 inch connector with a Luer-lock fitting, followed by PVC tubing with an internal diameter of 1/4 inch and a length of 270 cm, extending to the operating table. A tolerance of ±5% shall be permitted for the specified lengths. Suction Line – Vent The vent suction line shall be colour-coded and shall consist of: PVC tubing with an internal diameter of 1/4 inch and a length of 100 cm. 1/4 × 3/8 inch connector connected to silicone tubing with an internal diameter of 3/8 inch and a length of 60 cm. 3/8 × 1/4 inch connector with a Luer-lock fitting, followed by PVC tubing with an internal diameter of 1/4 inch and a length of 210 cm, extending to the operating table. A one-way valve shall be incorporated into the line, oriented to allow flow from the patient towards the extracorporeal circulation machine. The permitted tolerance for the specified lengths shall be ±5%. External Suction Line A colour-coded external suction line, 5 m long (±5%), shall be provided, with a terminal 1/4 × 1/4 inch connector. Each of the three suction lines shall be identified by a different colour. Gas Blender Connection The system shall include a connection for the gas blender, equipped with a filter. Main Roller Pump Tubing Segment The main roller pump line shall have the following sequential configuration: PVC tubing with an internal diameter of 3/8 inch and a length of 60 cm. 3/8 × 1/2 inch connector. Silicone tubing with an internal diameter of 1/2 inch and a length of 60 cm. 1/2 × 3/8 inch connector. Final segment of PVC tubing with an internal diameter of 3/8 inch and a length of 60 cm. One of the connectors shall be equipped with a Luer-lock port for measuring pre-membrane pressure. A tolerance of ±5% shall be permitted for each specified length. Priming Line The line for priming the extracorporeal circulation machine shall be 130 cm long (±5%) and shall include three spike adapters. Extension Line with One-Way Valve and Pressure Transducer Protector An extension line shall be included, consisting of an initial segment 20 cm long, followed by a one-way valve. After the valve, the line shall continue for 80 cm up to a three-way stopcock. A pressure monitoring line, 80 cm long and equipped with a pressure transducer protector, shall extend from the three-way stopcock. A tolerance of ±5% shall be permitted for all specified lengths. Additional Pressure Monitoring Line An additional pressure monitoring line, 80 cm long (±5%), equipped with a pressure transducer protector, shall be provided. Blood Transfer Bag The system shall include a sterile blood transfer bag with a capacity of at least 2,000 ml. Additional Connectors The system shall include: One straight male-to-female one-way double connector. Three three-way stopcocks. Reservoir Level Sensor Each sterile adult perfusion set shall be supplied with an adhesive patch and a sensor for monitoring the blood volume level in the reservoir (Level Sensor). Oxygenator The oxygenator shall meet the following requirements: Flow rate: 5 to 8 L/min. Integrated arterial filter. Priming volume: maximum 450 ml. Reservoir capacity: 4,000 to 4,500 ml. Two cardioplegia connectors. Blood Cardioplegia Set Inlet Lines and Connections The initial section of the set shall consist of two PVC lines with dimensions of 1/4 × 1/16 × 20 cm, each equipped with a spike at the proximal end. The two lines shall be joined via a Y-connector. A PVC line with dimensions of 1/4 × 1/16 × 90 cm shall extend from the Y-connector and shall be connected, via a 1/4 × 1/4 inch connector, to silicone tubing with dimensions of 1/4 × 1/16 × 40 cm. The silicone tubing shall be connected to one branch of the next Y-connector. Another line shall be connected to the same Y-connector, consisting of a PVC segment with dimensions of 1/4 × 1/16 × 100 cm, a 1/4 × 1/4 inch connector, and a silicone segment with dimensions of 1/4 × 1/16 × 40 cm. Line to the Heat Exchanger A PVC line with dimensions of 1/4 × 1/16 × 10 cm shall extend from the common Y-connector. It shall be followed by a 1/4 × 1/4 inch connector with a male cap, and then by a PVC line with dimensions of 1/4 × 1/16 × 50 cm, which shall be connected
- Internal identifier
- 01
Purpose
- Main nature of the contract
- Supplies
- Main classification
- (cpv): 33000000 Medical equipments, pharmaceuticals and personal care products
Place of performance
- Postal address
- 1000
- Town
- Skopje
- Country subdivision (NUTS)
- Скопски (MK008)
- Country
- North Macedonia
Estimated duration
- Duration
- 1 Year
Value
- Estimated value excluding VAT
- 10 996 480,00 MKD
General information
- Reserved participation
- Participation is not reserved.
Procurement Project not financed with EU Funds.
- The procurement is covered by the Government Procurement Agreement (GPA)
- yes
Selection criteria
- Sources of selection criteria
- Procurement Document
Procurement documents
- Address of the procurement documents
- https://www.e-nabavki.gov.mk/PublicAccess/home.aspx#/dossie/4a1e12ed-22dd-45e1-bde0-f64dffac1c66/1
Terms of procurement
Terms of submission:
- Electronic submission
- Allowed
- Address for submission
- https://www.e-nabavki.gov.mk/
- Languages in which tenders or requests to participate may be submitted
- Macedonian
- Electronic catalogue
- Not allowed
- Deadline for receipt of tenders
- 07/12/2026 12:00:00 (UTC+01:00) Central European Time, Western European Summer Time
- Duration during which the tender must remain valid
- 90 Days
Terms of contract:
- The execution of the contract must be performed within the framework of sheltered employment programmes
- No
- Electronic invoicing
- Not allowed
- Electronic ordering will be used
- no
- Electronic payment will be used
- no
Techniques
Framework agreement:
No framework agreement
Information about the dynamic purchasing system:
No dynamic purchase system
Further information, mediation and review
- Review organisation
- State Commission for Public Procurements Appeals
- Organisation providing more information on the review procedures
- PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES
Procedure
Procedure
- Title
- Integrated systemic perfusion system designed for an extracorporeal circulation machine.
- Description
- Integrated systemic perfusion system designed for an extracorporeal circulation machine.
- Procedure identifier
- 996ff217-9431-44e4-9382-daee8c5e211a
- Internal identifier
- 19420/2026
- Type of procedure
- Open
- The procedure is accelerated
- no
Purpose
- Main nature of the contract
- Supplies
- Main classification
- (cpv): 33000000 Medical equipments, pharmaceuticals and personal care products
Place of performance
- Postal address
- St. Mother Teresa nr. 17
- Town
- Skopje
- Country subdivision (NUTS)
- Скопски (MK008)
- Country
- North Macedonia
Value
- Estimated value excluding VAT
- 10 996 480,00 MKD
General information
Legal basis:
Directive 2014/24/EU
Grounds for exclusion
- Sources of grounds for exclusion
- Procurement Document
Organizations
Buyer
- Official name
- PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES
- dini.ism@hotmail.com
- Legal type of the buyer
- Body governed by public law, controlled by a central government authority
- Activity of the contracting authority
- Health
ORG-0001
- Official name
- PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES
- Registration number
- 7929420
- Postal address
- St. Mother Teresa, nr. 17
- Town
- Skopje
- Country subdivision (NUTS)
- Скопски (MK008)
- Country
- North Macedonia
- Contact point
- Sonja Janakieva
- dini.ism@hotmail.com
- Telephone
- 023113116
- Fax
- 023113116
Roles of this organisation:
- Buyer
- Organisation providing more information on the review procedures
ORG-0002
- Official name
- State Commission for Public Procurements Appeals
- Registration number
- 6428045
- Postal address
- 54 St. Cyril and Methodius Blvd., 3rd Floor
- Town
- Skopje
- Postcode
- 1000
- Country subdivision (NUTS)
- Скопски (MK008)
- Country
- North Macedonia
- Contact point
- State Commission for Public Procurements Appeals
- dkzjn@gs.mk
- Telephone
- 023251260
- Fax
- 023251260
Roles of this organisation:
- Review organisation
ORG-0000
- Official name
- Publications Office of the European Union
- Registration number
- PUBL
- Town
- Luxembourg
- Postcode
- 2417
- Country subdivision (NUTS)
- Luxembourg (LU000)
- Country
- Luxembourg
- Telephone
- +352 29291
- Internet address
- https://op.europa.eu
Roles of this organisation:
- TED eSender
Notice information
778035-2026 - Competition
North Macedonia – Medical equipments, pharmaceuticals and personal care products – Integrated systemic perfusion system designed for an extracorporeal circulation machine.
OJ S 217/2026 09/11/2026
Contract or concession notice – standard regime
Supplies
- Notice identifier/version
- d228b54b-c20f-4264-bc06-ce00c1d07d14 - 01
- Form type
- Competition
- Notice type
- Contract or concession notice – standard regime
- Notice subtype
- 16
- Notice dispatch date
- 06/11/2026 13:00:27 (UTC+00:00) Western European Time, GMT
- Languages in which this notice is officially available
- English
- Notice publication number
- 778035-2026
- OJ S issue number
- 217/2026
- Publication date
- 09/11/2026
Sources
Explore more tenders
More tenders from PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES
- Electrical energyPHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES · Skopje, North Macedonia
- Medical and Non-Medical Equipment ServicePHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES · Skopje, North Macedonia
- Medicines on a conditional budgetPHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES · Skopje, North Macedonia
Similar active tenders
- Procurement of Microbiological TestsPHI Institute of Public Health of Republic of North Macedonia Skopje · Skopje, North Macedonia
- Procurement of Microbiological TestsPHI Institute of Public Health of Republic of North Macedonia Skopje · Skopje, North Macedonia
- Lijekovi 4Sveučilišna klinika za neurologiju -Skoplje · Skoplje, Sjeverna Makedonija
- Medical consumablesPHI University Clinic for Surgical Diseases St. Naum Ohridski-Skopje · Skopje, North Macedonia
- Laboratory reagents and consumables 2Public Health Facilility General Hospital with extended scope of practice · Prilep, North Macedonia
- Laboratory consumablesPHO Centar For Public Health - Skopje · Skopje, North Macedonia